PVC Insulated Power Cable
1 Conductor:Copper or Aluminium 2 Insulation:PVC or XLPE 3 Voltage:Low/Medium/High Voltage 4 Standard:IEC 60502,GB/T 12706
Technical Parameters of our Power Cable
1). Standard: IEC60502; GB/T12706;IEC 60840;IEC62067;GB/T 11017;GB/Z 18890
2). Detailed description or construction:
* Conductor: compacted or uncompacted copper or aluminium
* Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC)
* Filler: Polypropylene filament with lapped binding tape
* Binder: Binding tape
* Inner sheath: Polyvinyl chloride (PVC)
* Armour: Galvanized steel wire armored (SWA) or steel tape armored (STA)
*Sheath: Polyvinyl chloride (PVC)
3). The rated voltages U0/U(Um) of the cables considered in this standard are as follows:
U0/U(Um) =0.6/1(1.2)-3.6/6(7.2)-6/10(12)-6.35/11(12)-8.7/15(17.5)-12/20(24)-12.7/22(24)-18/30(36)-19/33(36)-26/35(40.5)KV
4). Voltage:
0.6/1kV, 1.8/3kV, 3.6/6kV, 6/10kV,6.35/11kV, 8.7/15kV, 12/20kV,12.7/22kV, 18/30kV,19/33kV,26/35kV
In the voltage designation of cables U0/U(Um):
* U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
* U is the rated power frequency voltage between conductors for which the cable is designed;
* Um is the maximum value of the "highest system voltage" for which the equipment maybe used.
5). Application:
For laying indoors, in tunnel or cable trench with large difference of level able to bear external mechanical forces.
6). Marking: According to the customers' requirements
7). Nominal cross-sectional areas:
1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2, 800mm2
Operating characteristic: |
Tating voltageU./U: 0.6/1KV Long-term working temperature of cable: PVC insulation 70°CMinimum laying temperature of cables: 0°C Minimum curving semidiamenter of cables:Single core nonarmoured cables: 15DMultiple nonarmoured cables: 12D Single core armoured cables: 20DMultiple armoured cables: 15D Remarks: S is actual outer diameter of cables. Unit:mm |
specification
Type(Cu,Al) | Quantity of core | Nominal section(mm2) |
VV VV22 VV23 YJV YJV22 YJV23 | 1 | 1.5-630 (armoured cable 10-630) |
2 | 1.5-185 (armoured cable 4-185) | |
3 | 1.5-300 (armoured cable 4-300) | |
4 3+1 | 1.5-300 (armoured cable 4-300) | |
5 3+2 4+1 | 1.5-300\ (armoured cable 4-300) |